| Product ID | SPRAY-L-005 |
|---|---|
| Key Benefits | Repair + Hydration |
| Target Audience | women&men skincare |
| Package | 1 box*1.67 fl.oz. / 50mL |
| Shelf life | 3 years |
| MOQ | 50kg |
| Delivery Time | 40-60 days(Once the design draft is finalized) |
Aqua, Glycerin, Pentylene Glycol, Hexylene Glycol, Hydroxyacetophenone, Collagen, Trehalose, Sodium Chloride, Sodium Hyaluronate, Centella Asiatica Flower/Leaf/Stem Extract, Dipotassium Glycyrrhizate
Sensitive skin; Dry air-conditioned environments; Outdoor commuting; On-the-go hydration and repair; Those looking to set their makeup
Test Protocol: This test evaluated the repair efficacy claims of the submitted sample by measuring specific parameters in 30 healthy Asian (Chinese) subjects (male and female) before and after product application. The study included 30 valid subjects, achieving a 100% validity rate.
| Skin transepidermal water loss (TEWL) value | |
| 2 hours after using the sample | Among the 30 subjects, the rate of change in transepidermal water loss (TEWL) for the skin in the test area was -28.39%, while that for the control area was -23.03%; a significant difference was observed between the two groups. |
|---|---|
| 4 hours after using the sample | Among the 30 subjects, the rate of change in transepidermal water loss (TEWL) for the skin in the test area was -32.26%, while that for the control area was -24.34%; a significant difference was observed between the two groups. |
| conclusion | The results indicate that the test samples exhibit repair efficacy after 2 and 4 hours of use. |
| Skin Hemoglobin EI Value | |
| 2 hours after using the sample | The rate of change in the skin hemoglobin EI value in the test area for the 30 subjects was -20.37%, while that in the control area was -12.26%; there was no significant difference between the two groups. |
| 4 hours after using the sample | The rate of change in the skin hemoglobin EI value in the test area for the 30 subjects was -24.44%, while that in the control area was -16.09%; there was no significant difference between the two groups. |
Statistical analysis was performed using SPSS 26.0. Test data were subjected to a normality test; data following a normal distribution were analyzed using the t-test, while non-normally distributed data were analyzed using the rank-sum test. A significance level of p < 0.05 was adopted, indicating statistical significance within a 95% confidence interval.
Regarding the correlation between the test parameter and the efficacy claim, “repair” refers to the maintenance of the treated area in a normal state; therefore, the repair efficacy of the sample can be evaluated by measuring improvements in Transepidermal Water Loss (TEWL), stratum corneum hydration, or the hemoglobin Erythema Index (EI) before and after product application.
Stratum corneum hydration was measured using the internationally recognized capacitance method, which assesses changes in skin capacitance to determine if stratum corneum hydration has increased; higher measured values indicate higher hydration levels in the stratum corneum following sample application. TEWL serves as an indicator of skin barrier function; a lower TEWL value signifies reduced transepidermal water loss and superior barrier function. A lower hemoglobin EI value indicates a lower hemoglobin content in the skin. The sample is considered to possess repair efficacy if, following application, there is a significant decrease in TEWL and a significant increase in stratum corneum hydration, or a significant decrease in the hemoglobin EI value.
2.Moisturizing Efficacy
This test establishes an *in vitro* protocol to evaluate the moisturizing efficacy of cosmetics and raw materials by measuring their water-retention performance in a dry environment.
*In Vitro* Moisturizing Efficacy Evaluation: Three replicates were set up for each test group. Negative and positive control groups were included alongside the test groups; the positive control used glycerol, while the negative control used purified water. The procedure for the controls was identical to that for the test samples: A clean, dry, stoppered glass weighing bottle was placed in a desiccator (maintained at 25°C ± 1°C with indicating silica gel desiccant at the bottom) for 24 hours prior to the test, and its weight (m0) was accurately recorded. At room temperature, 1 mL of nutrient agar was dispensed into the weighing bottle; once solidified, 200 μL of the test sample was added, and the total mass (m1) was accurately recorded. The bottle was then placed in the desiccator containing the desiccant for a total duration of t = 8 hours. For both the sample and control groups, the weighing bottles were removed from the desiccator at 2, 4, 6, and 8 hours; the stoppers were secured, and the weight (mt) was accurately recorded.
Moisturizing performance was evaluated based on the percentage of weight loss due to drying.
Test Conclusion: Under the specified test conditions, the results showed that the percentage of weight loss for the sample group at 2, 4, 6, and 8 hours was lower than that of the negative control group, indicating that the sample possesses moisturizing efficacy.
Molecular
HIGH-PERFORMANCE SKINCARE SOLUTIONS
Powered by recombinant human Type III collagen, we provide professional skincare solutions for skin repair, barrier care, anti-aging and customized OEM/ODM development.
News